Camrea inspections.

Level 1 chimney inspection.

Same fuel ,same appliance, same intended usage.

  • Check audit trail-certificate of compliance, data plates previous services records.
  • inspect exterior from the ground.
  • inspect appliance and installation for safety and compliance.
  • dismantle appliance.
  • clean the chimney/flue.
  • Examine debris.
  • brief camera inspection.
  • reassemble the appliance.
  • type 2 smoke test.
  • check air ventilation CO alarm and fuel.

Level 2 Chimney inspection.

  • Failure or faults on level 1 chimney inspection that have not been successfully identified .
  • change of fuel appliance of intended use.
  • change of ownership or tenancy.
  • catastrophic event such as chimney fire, house fire or a structural refurbishment at the request of EHO,LABC, Insurance company.
  • all operations in level one chimney inspection unless done recently.
  • Type 1 smoke test or leakage test
  • Full camera inspection
  • Recommission appliance provided the chimney and appliance are useable  and measure flue draft 
  • Report findings.

 

 

 

 

 